Home > Error Code > Ftp Error 16550

Ftp Error 16550

Contents

User FTP: These are some questions you can ask the User to try to determine what their problem is: · Can you look at the LOGWND and see what error you A new request may be initiated. 3xx Positive Intermediate reply The command has been accepted, but the requested action is being held in abeyance, pending receipt of further information. That's the answer I was looking for.Is there any way to force the job completion code to a different value? It displays the job name, start and stop time, and "return code", but apparently only for jobs with a non-zero return code. this contact form

Requested file action successful (for example, file transfer or file abort). 227 Entering Passive Mode 230 User logged in, proceed. 250 Requested file action okay, completed. 257 "PATHNAME" created. 300 Series Under the OPTIONS Tab of their active session select the SESSION OPTIONS Tab. Back to top viniIntermediateJoined: 12 Jan 2004Posts: 231Topics: 46Location: Maryland Posted: Fri Feb 13, 2004 4:18 pm Post subject: That indeed worked ..omitting the ASCII i.e. !!! I'd guess it's probably a seperate box (some sort of router/switch/firewall combo) attached to the m/f but that's only a guess. https://www.ibm.com/support/knowledgecenter/SSLTBW_2.2.0/com.ibm.zos.v2r2.halu001/ftpstret.htm

Eza1735i Std Return Code = 27550, Error Code = 00002

Tim Posts: 21Joined: Thu Mar 24, 2011 1:00 am Hasthanked: 0 time Beenthanked: 0 time Top Re: Controlling proc RC by enrico-sorichetti » Fri Mar 25, 2011 1:47 am Is After my job runs, the "return code" shows as 166. If it were to fail the second time, the completion code would and should be 166, but if the second attempt succeeds, I want the completion code to be 0.as said Make sure the PROMT FOR DESTINATION FILE NAMES box is checked and that TRANFER MODE is set to ASCII MVSFORUMS.comA Community of and for MVS Professionals FAQ Search Quick Manuals Register

In my case, when the ftp fails, the proc sleeps a few seconds then executes the ftp a second time and it succeeds. TYPE A and MODE B are mutually exclusive options EZA1736I PUT 'DK037.W037DCLM.PXCAP310.DCLMCIAC.TXT' MONTHLY\DCLMCIAC.TXT EZA1701I >>> SITE FIXrecfm 259 LRECL=259 RECFM=FB BLKSIZE=27972 500 'SITE FIXrecfm 259 LRECL=259 RECFM=FB BLKSIZE=27972': command not understood Huenger Portal Foro Menú Personal Bienvenido Invitado User: Pass: Ingresar automáticamente: Registrarte! Ftp Error Code 00002 IBM Reference: http://publibz.boulder.ibm.com/epubs/pdf/f1aa2032.pdf.

A PUT command would move data the other way. An FTP condition code of 0166 is usually an FTP return code of 16550, which means a GET was attempted but the data set being retrieved did not exist on the que es la solución a la edad promedia muy alta (50 años) de la gente de mainframe. http://www.unm.edu/~finteam/General/FTP.htm Otra 459 Votos Totales Mirar encuesta...

Code Description 100 Series Codes The requested action is being initiated, expect another reply before proceeding with a new command. 110 Restart marker reply. 120 Service ready in nnn minutes. 125 Mainframe Ftp Error Codes The User-process is discouraged from repeating the exact request (in the same sequence). The system returned: (22) Invalid argument The remote host or network may be down. It means that the receiving server was not available at the time of the transfer.

Eza1735i Std Return Code = 26530, Error Code = 00011

Service terminated. 232 Logout command noted, will complete when transfer done. 233 User is "logged out". check my blog Robert Sample Global moderator Posts: 3082Joined: Sat Dec 19, 2009 8:32 pmLocation: Bellevue, Iowa Hasthanked: 1 time Beenthanked: 176 times Top Re: Controlling proc RC by Tim » Fri Mar Eza1735i Std Return Code = 27550, Error Code = 00002 The reply code is a 3-digit number. Eza1735i Std Return Code = 10000, Error Code = 00008 Thnks.

I did remember towards end of the day and got the cause in its FTP error messages section !!! Default is filetype=seq Back to top viniIntermediateJoined: 12 Jan 2004Posts: 231Topics: 46Location: Maryland Posted: Thu Feb 12, 2004 3:11 pm Post subject: taltyman , Yes, both ends are MVS . The GET command moves data from the file prof on the foreign host (142.10.5.8) to the file temp on the local host (the host where the batch job is running). Although it is commonly used interactively, FTP can be used to tranfer files in batch mode which allows unattended file transfer. Eza1735i Std Return Code = 27553, Error Code = 00002

Program Linkage Example: LINKAGE SECTION. 01 LK-AREA. 05 LK-LNGTH PIC S9(4) COMP. 05 LK-TIME PIC 9(08). *==============================================================* PROCEDURE DIVISION USING LK-AREA. *==============================================================* *--------------------------------------------------------------* * M A I N L I N Obviar Búsqueda avanzada Índice general Cambiar tamaño de la fuente FAQ Registrarte Identificarte Información El tema requerido no existe. Índice general El Equipo • Borrar todas las cookies del Sitio • MODE B Sets the block mode. Top of Page URL :ftprc.html Revised:12/08/2004 Layout, design & revisions David E.

You only use that to communicate with jes (get output, submit job, etc) Back to top viniIntermediateJoined: 12 Jan 2004Posts: 231Topics: 46Location: Maryland Posted: Thu Feb 12, 2004 9:08 am Post Eza1701i EZA1475I Connection with 172.20.8.1 terminated EZA1735I FTP Return Code = 10000, Error Code = 00010 The JCL Step : //S5 EXEC PGM=FTP,PARM='(EXIT' //INPUT DD * 172.20.2.1 UIVS013 GREASE ASCII PUT WLFA.ASX810FA.OUT.SEQ An existing dataset named userid.NETRC, where userid submitted this job, will be used to retrieve userid and password information.

Use ATTN to interrupt.

Back to top viniIntermediateJoined: 12 Jan 2004Posts: 231Topics: 46Location: Maryland Posted: Mon Jan 19, 2004 11:40 am Post subject: Mike, The inconsistency of IP Address as shown in JCL vs. Back to top taltymanJCL Forum ModeratorJoined: 02 Dec 2002Posts: 310Topics: 8Location: Texas Posted: Thu Feb 12, 2004 6:04 pm Post subject: MVS systems are ebcdic, everything else is ascii. EZA1736I 172.20.8.1 EZA1554I Connecting to: 172.20.8.1 port: 21. Ftp Return Codes Enter account and resend command. 434 Log-out forced by operator action.

The message was picked up from one JCL and the STEp from other ..but they both give same error message. This may include errors such as command line too long. 501 Syntax error in parameters or arguments. 502 Command not implemented. 503 Bad sequence of commands. 504 Command not implemented for command not understood" message. I agree with NicC; user code should not be writing messages to the operator unless there is no better alternative, or the user code must report something to the operator.As far

The second digit is a grouping digit and encodes the following information: Range Purpose x0x Syntax These replies refer to syntax errors, syntactically correct commands that don't fit any functional category, Note that the example above is based on Version 3.1 of the IBM TCP/IP product.